TMH Series
Compact closed-loop voltage sensing for accurate AC and DC measurement.
The TMH family uses a closed-loop Hall-effect architecture to convert a primary current proportional to the measured voltage into an isolated secondary current. An external primary series resistor defines the measurement scale, while an external measurement resistor converts the secondary current into a voltage-image output.

Voltage measurement through an isolated closed-loop current architecture
The voltage to be measured is applied to the primary side through an external series resistor R1. This creates a primary current proportional to the applied voltage. The Hall element and internal compensation amplifier generate a secondary current that reproduces the measured signal while maintaining galvanic isolation between primary and secondary circuits.
Validated TMH configurations
Two controlled references are currently published. Each reference opens its complete technical datasheet.
| Reference | Rated input | System measuring capability | Primary current range | Turn ratio | Output current | Supply | Accuracy | Response | Isolation | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|
| TMH-05P3 PDF ↗ | 5 V | up to ±1200 V via external series resistor | ±7 mA | 5000 / 1000 | ±25 mA | ±12 to ±15 V | < ±0.5% | < 40 µs | 2.5 kV | Open PDF ↗ |
| TMH-10P3 PDF ↗ | 10 V | up to ±500 V via external series resistor | ±14 mA | 2500 / 1000 | ±25 mA | ±12 to ±15 V | < ±0.5% | < 40 µs | 2.5 kV | Open PDF ↗ |
Technical note covering measurement principle, application fit and reliability factors common to both references.
Shared performance platform across both TMH references
Where TMH fits best
The TMH technical documentation positions the family for isolated voltage feedback in power electronics and industrial control systems.
Electrical safety and material compliance
The controlled TMH documentation references IEC 60950-1, EN 50178 and SJ 20790. The safety information also states intended-use alignment with IEC 61010-1. CE conformity and RoHS / REACH declarations are available from ADISENS.
Need help choosing TMH-05P3 or TMH-10P3?
Share the measured voltage, primary scaling resistor, required output level, supply voltage and application environment with our technical team.
Request Technical Support →Need another voltage range or output configuration?
TMH can be reviewed for project-specific rated input voltages and output configurations. Technical feasibility validation is required before release.
Request a Custom TMH →