Current & Voltage Measurement in Railway Applications

Traction substations, onboard conversion, current and voltage measurement, protection selectivity and railway environmental constraints.

ADISENS Technical KnowledgeWeb article
RAILWAY ENGINEERING

Measurement is part of the traction-power protection architecture.

An electrified railway line behaves as a distributed power-conversion system. Energy from the public or dedicated grid is transformed, rectified where required, distributed through DC busbars and feeders, and finally delivered to the train through overhead line or third rail. Reliable current and voltage measurement supports protection selectivity, supply quality, energy management, diagnostics and network availability.

Protection

Fast overcurrent and short-circuit detection supports selective breaker operation.

Voltage quality

Continuous voltage supervision helps verify operation inside the permitted traction-voltage envelope.

Load sharing

Feeder and substation current measurements help balance traction demand and monitor regenerative-energy flow.

Predictive maintenance

Current and voltage trends can reveal progressive degradation before an outright failure.

01 · MEASUREMENT PRINCIPLE

Closed-loop Hall-effect current sensing

A magnetic core surrounds the primary conductor. A Hall element detects the magnetic flux in the air gap, while a compensation winding drives the net core flux toward zero. The resulting secondary current is proportional to the primary current and is galvanically isolated from the power circuit.

Primary conductor
→
Magnetic core + Hall element
→
Compensation loop
→
Signal conditioning
→
Protection / SCADA / converter control

This principle combines wide bandwidth, good linearity and galvanic isolation, which are valuable in traction substations and onboard converters.

02 · DC TRACTION

Typical DC substation architecture

MV grid
→
Traction transformer
→
Rectifier
→
DC bus
→
Feeder breakers
→
Overhead line / third rail

Measurement points typically include transformer primary current, DC-bus or line voltage, and one current sensor per outgoing feeder. Feeder-current measurement is particularly important for protection selectivity so that only the faulted section is disconnected.

03 · AC TRACTION

Typical AC traction substation architecture

HV grid
→
Single-phase traction transformer
→
Traction bus
→
Feeder breakers
→
15 kV / 16.7 Hz or 25 kV / 50 Hz line

Unlike the DC architecture, the traction power path does not include a rectifier. Current measurement remains important on the transformer primary and outgoing feeders, while voltage measurement supervises the traction bus and network interface.

04 · ADISENS PORTFOLIO

Sensor families referenced for railway applications

Reference-level electrical performance and compliance must be checked on the applicable ADISENS datasheet.

05 · RAILWAY STANDARDS

Environmental and electrical constraints

ReferenceAreaWhy it matters
EN 50155Electronic equipment on rolling stockEnvironmental, electrical and reliability conditions
EN 61373Shock and vibrationMechanical robustness of onboard equipment
EN 45545Fire behaviourFire and smoke requirements for railway applications
EN 50163Traction supply voltagesDefines traction-system voltage conditions

Railway sensing also requires careful EMC design, galvanic isolation and controlled documentation because the measurement chain interfaces high-energy traction circuits with low-voltage protection and control electronics.

ADISENS ENGINEERING

Translate the measurement requirement into the right sensing architecture.