Current Sensors · PCB Mount · 3-pin primary
EM Series
Precision open-loop Hall-effect current sensing for compact power electronics.
The EM Series uses a high-sensitivity programmable Hall IC with factory digital calibration and compensation. It measures DC, AC and pulsed current with galvanic isolation, a 2.5 V centred analog output and support for 1, 2 or 3 primary turns.
15–50 ANominal current range
Up to ±150 AMeasuring range
4 kV ACDielectric strength
<2 µsTypical response
250 kHzBandwidth @ −3 dB
3-pin primaryPrimary topology

References & Documents
EM technical characteristics and datasheets
Each reference below links directly to its controlled ADISENS technical datasheet.
| Reference | Product code | Nominal current | Measuring range | Sensitivity | Supply | Output @ 0 A | Linearity | Accuracy @25°C | Response | Bandwidth | Isolation | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EM-15CP3 PDF ↗ | 10600015031100001 | 15 A | ±45 A | 41.67 mV/A | 4.75–5.25 V | 2.5 V typ. | 0.3% IPN typ. | ±1% IPN | <2 µs | 250 kHz | 4 kV AC | Open PDF ↗ |
| EM-25CP3 PDF ↗ | 10600025031100001 | 25 A | ±75 A | 25 mV/A | 4.75–5.25 V | 2.5 V typ. | 0.3% IPN typ. | ±1% IPN | <2 µs | 250 kHz | 4 kV AC | Open PDF ↗ |
| EM-50CP3 PDF ↗ | 10600050031100001 | 50 A | ±150 A | 12.5 mV/A | 4.75–5.25 V | 2.5 V typ. | 0.3% IPN typ. | ±1% IPN | <2 µs | 250 kHz | 4 kV AC | Open PDF ↗ |
PCB integration
EM: 3-pin primary architecture
The package is designed for direct through-hole integration of the primary conductor and secondary signal pins.
7.62 mmPrimary conductor pin pitch
2.54 mmSecondary signal pin pitch
6.3 mmElectrical clearance on PCB with recommended layout
9.5 mmPackage clearance / creepage
13 gTypical sensor mass
1, 2, 3 IN · 8, 9, 10 OUTPrimary IN / OUT terminal definition
Signal architecture
5 V analog measurement interface
VREF2.5 V typical reference output
VOUTAnalog output: VOUT = VOFF + Gth × IP
GNDSupply and signal ground
VCCPositive supply voltage, +5 V ±5%
Np = 1 / 2 / 3Selectable primary turns for effective range scaling
RL = 10 kΩReference load condition used for specified performance
Applications
Optimised for compact power-conversion electronics
AC Variable-Speed DrivesFast phase-current feedback for motor control.
Servo Motor DrivesHigh-bandwidth isolated current feedback.
Photovoltaic InvertersDC/AC converter stages and current-loop monitoring.
Battery ApplicationsCompact isolated current sensing in battery-fed power systems.
SMPS & UPSFast current measurement in switch-mode power supplies.
Welding Power SuppliesPulsed-current measurement and converter protection.
Standards & Compliance
Electrical-safety and environmental integration
IEC 61010-1Electrical safety framework for measurement and control equipment.
EN 50178Electronic equipment for use in power installations.
UL94-V0Housing material flammability classification.
CE / RoHS / REACHConformity and environmental declarations available from ADISENS.
Back to the family
Compare EM, EMT and EMK
Return to the family page to compare the three primary-conductor arrangements and available current ratings.
EM / EMT / EMK Family →Custom engineering
Need a project-specific configuration?
Share your current range, PCB constraints, available conductor routing and required dynamic performance.
Request a Custom EM →