Precision open-loop Hall-effect current sensing for compact power electronics.

The EMK Series uses a high-sensitivity programmable Hall IC with factory digital calibration and compensation. It measures DC, AC and pulsed current with galvanic isolation, a 2.5 V centred analog output and support for 1, 2 or 3 primary turns.

15–75 ANominal current range
Up to ±225 AMeasuring range
4 kV ACDielectric strength
<2 µsTypical response
250 kHzBandwidth @ −3 dB
5-pin primaryPrimary topology
ADISENS EMK series board-mount current sensor
References & Documents

EMK technical characteristics and datasheets

Each reference below links directly to its controlled ADISENS technical datasheet.

ReferenceProduct codeNominal currentMeasuring rangeSensitivitySupplyOutput @ 0 ALinearityAccuracy @25°CResponseBandwidthIsolationDatasheet
EMK-15CP5Available on request 1080001503130000115 A±45 A41.67 mV/A4.75–5.25 V2.5 V typ.0.3% IPN typ.±1% IPN<2 µs250 kHz4 kV ACOpen PDF ↗Available on request
EMK-25CP5Available on request 1080002503130000125 A±75 A25 mV/A4.75–5.25 V2.5 V typ.0.3% IPN typ.±1% IPN<2 µs250 kHz4 kV ACOpen PDF ↗Available on request
EMK-50CP5Available on request 1080005003130000150 A±150 A12.5 mV/A4.75–5.25 V2.5 V typ.0.3% IPN typ.±1% IPN<2 µs250 kHz4 kV ACOpen PDF ↗Available on request
EMK-75CP5Available on request 1080007503130000175 A±225 A8.33 mV/A4.75–5.25 V2.5 V typ.0.3% IPN typ.±1% IPN<2 µs250 kHz4 kV ACOpen PDF ↗Available on request
PCB integration

EMK: 5-pin primary architecture

The package is designed for direct through-hole integration of the primary conductor and secondary signal pins.

10.2 mmPrimary conductor pin pitch
2.54 mmSecondary signal pin pitch
8.5 mmElectrical clearance on PCB with recommended layout
9.5 mmPackage clearance / creepage
13 gTypical sensor mass
1–5 IN · 6–10 OUTPrimary IN / OUT terminal definition
Signal architecture

5 V analog measurement interface

VREF2.5 V typical reference output
VOUTAnalog output: VOUT = VOFF + Gth × IP
GNDSupply and signal ground
VCCPositive supply voltage, +5 V ±5%
Np = 1 / 2 / 3Selectable primary turns for effective range scaling
RL = 10 kΩReference load condition used for specified performance
Standards & Compliance

Electrical-safety and environmental integration

UL94-V0Housing material flammability classification.
CE / RoHS / REACHConformity and environmental declarations available from ADISENS.
Back to the family

Compare EM, EMT and EMK

Return to the family page to compare the three primary-conductor arrangements and available current ratings.

EM / EMT / EMK Family →
Custom engineering

Need a project-specific configuration?

Share your current range, PCB constraints, available conductor routing and required dynamic performance.