VCS-C Series
Compact rectangular current sensing for industrial power conversion.
The VCS-C family is designed for accurate measurement of DC, AC, pulsed and arbitrary-waveform currents. It provides galvanic isolation between the primary power circuit and secondary electronics, with a proportional analog voltage output and a compact rectangular aperture for busbar integration.
Eight validated ratings on a common mechanical platform
The published J4 references use the same 90 × 65 × 29 mm housing, 40.5 × 30.5 mm rectangular primary-conductor aperture, ±15 V supply and 4-pin Molex secondary connection.
VCS-C J4 technical datasheets
Click a reference to open its validated technical datasheet in a new tab.
| Reference | Nominal current | Measuring range | Sensitivity | Supply | Accuracy | Linearity | Response | Bandwidth | Isolation | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|
| VCS-C-200J4 PDF ↗ | 200 A | ±600 A | 20 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-400J4 PDF ↗ | 400 A | ±1200 A | 10 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-500J4 PDF ↗ | 500 A | ±1500 A | 8 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-600J4 PDF ↗ | 600 A | ±1800 A | 6.67 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-800J4 PDF ↗ | 800 A | ±2400 A | 5 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-1000J4 PDF ↗ | 1000 A | ±2500 A | 4 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-1200J4 PDF ↗ | 1200 A | ±2500 A | 3.33 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
| VCS-C-1500J4 PDF ↗ | 1500 A | ±2500 A | 2.67 mV/A | ±15 V | ±0.5% typ. | ±0.2% typ. | 5 µs | 25 kHz | 5.0 kV | Open PDF ↗ |
Stable open-loop sensing for electrically demanding environments
Typical accuracy at 25°C within the nominal current range.
Typical linearity error across the specified operating-temperature range.
Typical response time for current transients with di/dt above 50 A/µs.
Typical −3 dB bandwidth from DC.
Dielectric strength between primary and secondary circuits, 50 Hz for 1 minute.
Compact rectangular package for busbar installations.
One compact busbar-mount platform
The current ratings share a common mechanical architecture, simplifying integration across a wide current range.
Electrical safety and environmental documentation
The validated VCS-C datasheets reference IEC 61010-1 and EN 50178. CE conformity information and RoHS / REACH declarations are available from ADISENS.
Best-fit applications for VCS-C
The application mapping below follows the supplied VCS-C technical datasheets.
Need help selecting the right VCS-C?
Share your nominal current, peak current, busbar dimensions, supply and output requirements with our technical team.
Request Technical Support →Need another current range or integration?
Start from the closest validated VCS-C reference and define the electrical or mechanical changes required by your application.