VPS Series
Fast, isolated current measurement from 100 A to 600 A.
The VPS family is designed for electronic measurement of DC, AC, pulsed and mixed currents with galvanic isolation between the primary high-power circuit and the secondary electronics. One common mechanical platform covers the complete 100 A to 600 A range, simplifying design-in, stocking and product-line integration.
One mechanical design across the complete VPS range
The same envelope and mounting architecture are shared across VPS-100J4 to VPS-600J4, helping engineers standardise cable and busbar integration while retaining several current ratings on the same platform.
Thermal drift of offset voltage.
Thermal drift of output gain.
di/dt accurately followed.
Linearity error at 25°C.
Accuracy at nominal current, 25°C.
Current consumption from 0 to ±IPN.
VPS technical characteristics and datasheets
All six validated references are directly accessible from the table below.
| Reference | Product code | Nominal current | Measuring range | Supply | Linearity | Accuracy | Response | Bandwidth | Isolation | Operating temp. | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|
| VPS-100J4 PDF ↗ | 11800100031800001 | 100 A | ±300 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
| VPS-200J4 PDF ↗ | 11800200031800001 | 200 A | ±600 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
| VPS-300J4 PDF ↗ | 11800300031800001 | 300 A | ±900 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
| VPS-400J4 PDF ↗ | 11800400031800001 | 400 A | ±1200 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
| VPS-500J4 PDF ↗ | 11800500031800001 | 500 A | ±1200 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
| VPS-600J4 PDF ↗ | 11800600031800001 | 600 A | ±1200 A | ±15 VDC | < ±0.5% | < ±1% | < 3.0 µs | 50 kHz | 3.0 kV | −40 to +85°C | Open PDF ↗ |
Compact busbar and cable integration
The VPS mechanical envelope is shared across the complete range and is designed around a 32 mm primary through-hole.
Standard 4-pole Molex interface
Best-fit applications for the VPS Series
Electrical safety and environmental compliance
Need help selecting the right VPS?
Share the nominal current, peak current, busbar or cable geometry, switching frequency and application environment with our technical team.
Request Technical Support →Need another current or connection configuration?
ADISENS can review project-specific current ratings, connector adaptations and integration requirements.