Career Knowledge Partnership
Current Sensors · Open Loop · Hall Effect

VPS Series

Fast, isolated current measurement from 100 A to 600 A.

The VPS family is designed for electronic measurement of DC, AC, pulsed and mixed currents with galvanic isolation between the primary high-power circuit and the secondary electronics. One common mechanical platform covers the complete 100 A to 600 A range, simplifying design-in, stocking and product-line integration.

100–600 ANominal current range
Up to ±1200 APrimary measuring range
3.0 kVIsolation voltage
< 3.0 µsResponse time
50 kHzBandwidth @ −3 dB
Ø32 mmPrimary through-hole
ADISENS VPS open-loop current sensor
Engineering value

One mechanical design across the complete VPS range

The same envelope and mounting architecture are shared across VPS-100J4 to VPS-600J4, helping engineers standardise cable and busbar integration while retaining several current ratings on the same platform.

< ±1 mV/°C

Thermal drift of offset voltage.

< ±0.05%/°C

Thermal drift of output gain.

> 50 A/µs

di/dt accurately followed.

< ±0.5%

Linearity error at 25°C.

< ±1%

Accuracy at nominal current, 25°C.

< 15 mA

Current consumption from 0 to ±IPN.

References & Documents

VPS technical characteristics and datasheets

All six validated references are directly accessible from the table below.

Reference Product code Nominal current Measuring range Supply Linearity Accuracy Response Bandwidth Isolation Operating temp. Datasheet
VPS-100J4 PDF ↗ 11800100031800001 100 A ±300 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
VPS-200J4 PDF ↗ 11800200031800001 200 A ±600 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
VPS-300J4 PDF ↗ 11800300031800001 300 A ±900 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
VPS-400J4 PDF ↗ 11800400031800001 400 A ±1200 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
VPS-500J4 PDF ↗ 11800500031800001 500 A ±1200 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
VPS-600J4 PDF ↗ 11800600031800001 600 A ±1200 A ±15 VDC < ±0.5% < ±1% < 3.0 µs 50 kHz 3.0 kV −40 to +85°C Open PDF ↗
Custom VPS Need another current rating, connector or project-specific configuration?
Request a Custom Product →
Mechanical integration

Compact busbar and cable integration

The VPS mechanical envelope is shared across the complete range and is designed around a 32 mm primary through-hole.

Ø32.0 mmPrimary through-hole
70 mmBody width shown in controlled drawing
3 × Ø4.6 mmMounting holes
0.75 N·mRecommended M4 screw torque
210 gSensor mass
Common envelopeShared from 100 A to 600 A
Secondary connection

Standard 4-pole Molex interface

Molex 220410414-pole secondary connector
Molex 22011042Crimp housing
Molex 08500113Crimping terminal
Polarity indicationVOUT is positive when primary current follows the direction arrow on the label.
Standards & Compliance

Electrical safety and environmental compliance

CEEU conformity information available from ADISENS on request.
RoHS / REACHEnvironmental compliance declarations available on request.
Selection support

Need help selecting the right VPS?

Share the nominal current, peak current, busbar or cable geometry, switching frequency and application environment with our technical team.

Request Technical Support →
Custom engineering

Need another current or connection configuration?

ADISENS can review project-specific current ratings, connector adaptations and integration requirements.

Request a Custom VPS →